Skip to the sheet
Tailgate BriefSTSC study sheets
Menu

Sheet 10Domain 1 of 5 · Safety Program Implementation

HazCom, respirators and sanitation for STSC candidates

Your crew starts a coating job in a closed stairwell on Monday, and by Friday you need answers on respirators, Safety Data Sheets (SDS) and the hand-wash station. Respirators and hazard communication (HazCom) live in general-industry standards that the construction rules adopt by reference; sanitation has its own construction text. This sheet starts by sorting out which rule book applies to each.

Two rule books, one site

In 29 CFR, Part 1910 is general industry and Part 1926 is construction. Respiratory protection on your site is 29 CFR 1910.134, pulled in by 29 CFR 1926.103, and HazCom is 29 CFR 1910.1200, pulled in by 29 CFR 1926.59. A 1910 citation on a respirator or HazCom card is the right rule book, so read past it. Sanitation is construction's own: 29 CFR 1926.51.

Which rule book each topic uses

Construction section and the rule it applies
TopicConstruction sectionWhat it applies
Respiratory protection29 CFR 1926.10329 CFR 1910.134, the general-industry respirator standard
Hazard communication29 CFR 1926.5929 CFR 1910.1200: labels, SDS, written program, training
Sanitation29 CFR 1926.51Its own text: drinking water, toilets, washing, food handling
Respirators for silica tasks29 CFR 1926.1153Construction's silica standard; the respirator program under it follows 1910.134

Checked against eCFR on Oct 12, 2026. Pictograms, signal words and the 16 SDS sections are on the HazCom labels sheet.

Respirator types a supervisor will issue

Filtering facepiece
The disposable N95 type. It is tight-fitting, so the fit-testing rules apply when its use is required. A worker who wears one voluntarily gets the information in Appendix D of 29 CFR 1910.134.
Elastomeric half or full facepiece
A reusable rubber or silicone mask with replaceable filters or cartridges. Even voluntary use brings the wearer into the written program for medical evaluation, cleaning and storage (1910.134(c)(2)(ii)).
Powered air-purifying respirator (PAPR)
A battery blower pushes filtered air into a tight-fitting facepiece or a loose hood or helmet.
Supplied-air and SCBA
Atmosphere-supplying respirators bring clean air from a source. Air-purifying types cannot be used where the air is immediately dangerous to life or health (IDLH) or short of oxygen; these can, in the setups 1910.134(d)(2) allows.

Check your respirator and HazCom calls

The masks, the paperwork and the plumbing: respirator selection and fit, SDS and labels, toilets, drinking water and wash stations.

Card 1 of 15 · 0 right

Card 1

A laborer will wear a half-mask elastomeric respirator for the first time to scrape lead paint. Which sequence is required before the laborer uses it on the job?

Pick an answer. A short note for each option, A to D, appears here.

Card 2

A new spray-applied concrete sealer came onto the site this week, and two workers applying it report stinging eyes. Under HazCom, what training should the supervisor confirm the crew received?

Pick an answer. A short note for each option, A to D, appears here.

Card 3

A crew is applying epoxy coatings on a bridge deck. Which provision BEST meets the washing-facility requirement of 29 CFR 1926.51 for this crew?

Pick an answer. A short note for each option, A to D, appears here.

Card 4

A carpenter passed a fit test on one half-mask respirator 5 months ago and is now issued a different make and model of half mask. What is required before the new respirator is used?

Pick an answer. A short note for each option, A to D, appears here.

Card 5

A building project has 45 workers on site and no sewer connection. Under 29 CFR 1926.51, what is the MINIMUM number of toilet facilities required?

Pick an answer. A short note for each option, A to D, appears here.

Card 6

A crew will weld galvanized steel inside a partly enclosed stairwell. What should the supervisor do FIRST to select the right respiratory protection?

Pick an answer. A short note for each option, A to D, appears here.

Card 7

Several members of a drywall crew have limited reading ability. What is the BEST way to deliver the site's hazard communication training?

Pick an answer. A short note for each option, A to D, appears here.

Card 8

Which drinking-water setup meets 29 CFR 1926.51 for a construction crew?

Pick an answer. A short note for each option, A to D, appears here.

Card 9

A crew wears half-mask respirators with organic vapor cartridges while applying a solvent-based coating. How should the supervisor determine when the cartridges are replaced?

Pick an answer. A short note for each option, A to D, appears here.

Card 10

Under the Hazard Communication Standard as applied to construction, what must the employer do with the Safety Data Sheet for each hazardous chemical used on site?

Pick an answer. A short note for each option, A to D, appears here.

Card 11

A crew will grind a concrete slab and then apply a solvent-based sealer in the same enclosed area during one shift. The exposure assessment shows both hazards need respiratory protection. Which air-purifying respirator setup should the supervisor select?

Pick an answer. A short note for each option, A to D, appears here.

Card 12

A new adhesive's label shows a flame pictogram and the signal word 'Danger.' What does the signal word 'Danger' tell the crew?

Pick an answer. A short note for each option, A to D, appears here.

Card 13

A worker who passed a respirator fit test 11 months ago reports for a silica task wearing a new full beard. The task requires a tight-fitting half-mask. What should the supervisor do?

Pick an answer. A short note for each option, A to D, appears here.

Card 14

An air-sampling result shows a worker's exposure to a dust at 8 times its PEL. Which respirator has the LOWEST assigned protection factor that is still adequate?

Pick an answer. A short note for each option, A to D, appears here.

Card 15

A worker is splashed in the eyes with a new form-release agent. Which section of the Safety Data Sheet should the supervisor check FIRST for immediate care?

Pick an answer. A short note for each option, A to D, appears here.

    What a written respirator program covers

    • How respirators are selected for each task and exposure
    • Medical evaluation and fit testing of the people who must wear them
    • Use in routine work and in foreseeable emergencies
    • Cleaning, storage, inspection, repair and retirement
    • Breathing-air quality for atmosphere-supplying respirators
    • Training on the hazards and on correct use
    • Regular checks that the program works
    • A program administrator trained to run it (1910.134(c)(3))

    Mobile crews, nonpotable water and other employers' chemicals

    Do mobile crews need toilets at each stop?

    Not when they have transportation readily available to nearby toilet facilities. 29 CFR 1926.51(c)(4) exempts mobile crews in that position; a fixed site sizes its toilets to the crew using Table D-1 in the same section.

    Can nonpotable water be used on a construction site?

    Yes, for uses such as firefighting or cleaning equipment, as long as its outlets are marked as unsafe for drinking, washing or cooking and it never cross-connects with the drinking supply (29 CFR 1926.51(b)).

    Who tells other contractors about the chemicals your crew brings on site?

    Your company does. On multi-employer sites, 29 CFR 1910.1200(e)(2) requires the written HazCom program to say how other employers get access to the SDS and learn the precautions and the labeling system.

    Next sheets

    Ten cards at lunch beats an hour on Sunday

    Short sets on your iPhone keep this domain fresh between site walks.